Optosky always takes high-tech products as the core,both inside and outside, soft and hard, with stylish design and full sincerity, to create more efficient and professional new products of the times. The newly de-veloped LC3200 high performance liquid chromatography system meets the constantly upgraded regulatory requirements and redefines the appearancce design of domestic liquid phase, perfects the auto-maticity, continuity and integrity of the analysis process, demonstrates the stability of laboratory results, and meets the feasibility of low-cost and high-efficiency operation of laboratories.
Features:
●Calibration automation control provides high accuracy
●Integrated solvent switching system the high-pressure binary can have the function of double high-pressure binary, even double four high-pressure
●High efficiency autosampler and autodillusion function
●Pressure range up to 600 bar
●Flow leak free detector provides warning in time
●Corrosionresistance materials used for black housing surface
Application:
●Colorant brilliant blue, para bluel
●Glyphosatel
●Amino acid
Performance Specification of P3200 Pump
Performance Specification |
Flow Rate |
0.001 -10.000mL/min (Step:0.00mL /min) |
Flow Accuracy |
<±0.2% |
Flow Stability |
RSD<0.06% |
Max Pressure |
70MPa |
Pressure Display Error |
±0.3MPa |
Pressure Pulsation |
<0.1MPa |
Gradient Composition Range |
0-100%,0.01%delta |
Gradient Mixing Accuracy |
<±0.5%, does not vary with backpressure |
Gradient Composition Accuracy |
<0.1% RSD |
Communication Mode |
UDP |
Dimension/Weight (Long by wide by high) |
450x350mm x180mm/18kg |
Power Supply |
110-220V,50-60Hz |
Power |
300W |
Performance Specification for O3200 column oven
Performance Specification |
Models |
3210 |
3220 |
Temperature range |
Ambient temperature+5°C~99°C |
Ambient temperature+5°C~85°C |
Accuracy |
±0.1°C |
±0.1°C |
Precision |
<0.1°C |
<0.1°C |
Communicate mode |
485line/UDP |
485line/UDP |
Dimension/Weight (Long by wide by high) |
120x65x570mm/4.2kg |
435x137x450mm/11kg |
power supply/Power |
AC220V±10%,50Hz/110W |
AC110-220V,50-60Hz/130W |
Performance Specification of D3230 detector
Performance Specification |
Number of arrays |
512 |
Light resource |
Deuterium lamp |
Array resolution |
1.2nm |
Spectral resolution |
2.4nm(slit100pm) |
Wavelength range |
190-800nm |
Wavelength accuracy |
±1.0nm |
Dynamic short-term noise |
<±1.0x10-5AU |
Dynamic baseline drift |
1.0x10-4AU/h |
Linearity range |
>2.0AU |
Detection pool withstand pressure |
1000psi |
Detection pool |
Analytics pool:10mm 11μl |
Semi-micro pool:5mm 2.5μl |
Analog signal output range |
-0.5-2.5AU |
Communication mode |
UDP |
Performance Specification of S3200 sampler
Performance Specification |
Injection range |
0-100pL(Standard ), 1-2000pL (Matching) |
Capacity |
2mLSample vials 120bits; 1mL Sample vials 21 0bits;compatible 4.0mLSample vials and 96-well plate |
Sample residue |
<0.002% |
Injection repeatability |
RSD<0.2% |
Max Pressure |
45MPa |
Injection speed |
10s or less |
Dimension/Weight |
440x378x180mm (Long by wide by high) /13kg |
Power Supply |
110-220V,50-60Hz |
Power |
30W |
Performance Specification of D3200 detector
Performance Specification |
Wavelength range |
190nm-800nm |
Light resource |
Deuterium lamp and Tungsten lamp |
Noise |
<±0.25x10-5AU |
Wavelength accuracy |
±1.0nm |
Sampling frequency |
5-80Hzs adjustable (Single wavelength mode) |
A wavelength of 1 .0s (Dual wavelength mode) |
Wavelength repeatability |
<±0.1nm |
Max Pressure |
1500psi |
Spectral bandwidth |
8nm |
Minimum detection concentration |
1x10-9g/mL |
Drift |
<0.5x10-4AU/h |
Linearity range |
>2.5AU (Customizable3.0AU) |
Detection pool |
Analytics pool:10mm 11μL |
Semi-preparation pool:5mm 2.5μL |
Time constant |
0.1s-5.0s adjustable |
Dimension/Weight |
440x378x160mm (Long by wide by high) /10kg |
power supply/Power |
110-220V, 50-60Hz/100W |