Applications | ATRP8300Pro Raman-IR Integrated Microscope Raman and Infrared in the Same Microscope: What Problem Does the ATRP8300Pro Solve?
One microscope can perform micro-Raman, micro-FTIR, and automated mapping imaging. This is not simply “two instruments bolted together.” It solves a long-standing pain point in materials, polymer, and nanotechnology research—measuring the same micro-area with two spectroscopic methods without positional misalignment.
01 A Problem a Graduate Student Encounters Every Day
Xiao Lin is a third-year doctoral student in the School of Materials Science, researching polymer thin films. She has a batch of blend film samples and wants to know whether two polymers are uniformly dispersed at the micro-scale. She first goes to the Raman room. Raman can clearly show the carbon-carbon double bond peak—a characteristic of one polymer. But there is a problem: the other polymer contains abundant hydroxyl and carbonyl groups, and these polar bonds have weak Raman signals or are even overwhelmed by fluorescence. So she moves the sample to the infrared room. Infrared is particularly sensitive to polar bonds such as hydroxyl and carbonyl, and the other polymer is clearly visible. But the carbon-carbon double bonds of the first polymer do not produce strong infrared signals. The bigger problem: two rooms, two instruments, two sample stages. The micro-area point she selected on the Raman instrument cannot be aligned to the same position after moving to the infrared instrument. The sample surface is only a few hundred micrometers across; once the stage moves, the coordinates are lost. She can only rely on experience: remember the location of a scratch in the Raman image, then visually search for it on the infrared instrument. Whether she finds it depends on luck.
This is not Xiao Lin’s problem alone. In fields such as polymers, composites, nanofilms, and biomedical coatings, almost everyone doing micro-area analysis has encountered the same dilemma: the same micro-area needs to be clearly characterized by two spectroscopic methods, but the two instruments are in two rooms and the positions never align.
The ATRP8300Pro aims to solve exactly this.
02 Why Must Raman and Infrared Be “Viewed Together”?
Many people encountering molecular spectroscopy for the first time ask: Raman can already measure molecular vibrations, so why do we still need infrared? The answer is: these two methods look at two sides of the same coin.
Every chemical bond in a molecule vibrates. But whether a vibrational mode can be seen by Raman depends on whether the vibration changes the molecule’s polarizability; whether it can be seen by infrared depends on whether the vibration changes the molecule’s dipole moment. These are two different criteria.
Symmetric, non-polar bonds—such as carbon-carbon double bonds (C=C), sulfur-sulfur bonds (S-S), and carbon-carbon single bonds—have large polarizability changes, strong Raman signals, and weak infrared signals.
Asymmetric, polar bonds—such as hydroxyl (O-H), carbonyl (C=O), amino (N-H), and carboxyl groups—have large dipole moment changes, strong infrared signals, and weak Raman signals.
In other words: Raman is good at seeing the “skeleton,” while infrared is good at seeing “functional groups.”
A common example is a blend of polyethylene and nylon. The hydrocarbon skeleton of polyethylene is clear in Raman; the amide bonds (N-H, C=O) in nylon are obvious in infrared. Raman alone cannot fully see nylon; infrared alone blurs the fine structure of polyethylene. This is why people who truly do material micro-area analysis say: “Raman and infrared are complementary, not substitutive.”
But complementary as they are, truly achieving “the same micro-area point measured by both methods” has historically been extremely costly—you need to precisely transfer the sample between two instruments with error controlled within a few micrometers. The ATRP8300Pro’s approach is: stop moving the sample; put both instruments into the same optical path.
03 What Is Difficult About Putting Two Instruments into One Microscope?
It sounds like “bolting them together,” but in practice it involves three hard engineering tasks.
First, the optical paths must switch seamlessly. Raman uses a laser excitation path: laser → objective → sample → backscattered light → spectrometer → CCD. Infrared uses another set: broadband source → beam splitter → objective → sample reflection → detector. The two optical paths must meet within the interface of the same microscope without interfering with each other. The ATRP8300Pro uses software-controlled optical path switching—click once on the computer, and the path switches from Raman to infrared without manually turning any screws.
Second, the micro-area position must be strictly aligned. The minimum Raman spot is less than 20 μm, and the minimum infrared spot is less than 50 μm. This means that when you select a point under the microscope and switch to another mode, the laser/infrared spot must fall on the same coordinate. This requires the sample stage positioning accuracy to reach 1 μm and movement resolution 0.1 μm—the ATRP8300Pro’s motorized two-dimensional stage meets this specification.
Third, autofocus and automatic scanning must truly work. Research users often need to perform mapping—point-by-point scanning over a 50 × 50 mm (optional 100 × 100 mm) area to generate a “chemical composition distribution map.” If every point requires manual focusing, very few points can be scanned in an entire evening. The MP version (Mapping model) is equipped with autofocus, with focusing accuracy ±0.2 μm, completed within 10 seconds; automatic scanning speed is 20 mm/s.
Only when these three things come together does “same micro-area, Raman then infrared” become an action that can be completed with a mouse, rather than an engineering project requiring two people for an afternoon.
ATRP8300Pro Core Parameters at a Glance
Raman excitation wavelengths: 532 / 633 / 785 / 830 / 1064 nm (dual-wavelength optional)
Spectrometer focal length: 210 / 350 / 510 / 810 mm (longer focal length gives higher resolution, up to 0.5 cm⁻¹)
04 How to Choose the Configuration: Focal Length, Wavelength, and Version Matrix
The ATRP8300Pro is not a one-size-fits-all device; it is a configuration matrix. For buyers, the key is to understand what samples your laboratory most often measures.
How to choose focal length?
FL210 (210 mm focal length): cost-effective tier, resolution about 2.2 cm⁻¹, suitable for ordinary polymers and preliminary material screening.
FL350 (350 mm): general-purpose tier, resolution 1.4 cm⁻¹, sufficient for most research scenarios.
FL510 (510 mm): high-resolution tier, resolution 0.9 cm⁻¹, suitable for samples with very close peak spacing (such as isomers and complex minerals).
FL810 (810 mm): top tier, resolution 0.5 cm⁻¹, suitable for nanomaterials, single crystals, and research-grade paper data requiring extremely high resolution.
The longer the focal length, the more expensive and larger the instrument, but the better it can separate closely spaced peaks. If your sample peaks are already well separated, FL210/350 is sufficient; if you need to publish in top journals and measure fine vibrational structures, FL510/810 is worth it.
How to choose wavelength?
532 nm: highest sensitivity, suitable for nanomaterials, carbon materials, and two-dimensional materials; but samples with strong fluorescence can fail.
633/638 nm: a compromise choice, with weaker fluorescence than 532 nm.
785 nm: general-purpose workhorse, suitable for most organic samples, polymers, and food.
1064 nm: best fluorescence suppression, suitable for dark samples, traditional Chinese medicines, dark plastics, and materials prone to fluorescence, but the detector switches to InGaAs and sensitivity decreases.
Practical configurations can choose dual wavelengths—for example, a 532 + 785 combination—balancing sensitivity and fluorescence suppression.
How to choose version?
Base: manual focusing, suitable for research groups with limited budgets that occasionally perform micro-area analysis.
AF: adds autofocus, suitable for laboratories that frequently change samples but do not perform large-area mapping.
MP: autofocus + automatic scanning mapping, suitable for research groups that need chemical imaging and “composition distribution map” papers.
There are also two detector options: LT (deep cooling to -30°C, ultra-long integration time up to 1.3 hours, suitable for extremely weak signals) and 5CM (cooled sCMOS, suitable for fast imaging).
05 Who Uses This Instrument?
The datasheet lists a long roster of users: Central South University, Tsinghua University, Xiamen University, Sichuan University, Chongqing University, Shenzhen University, Shanghai Jiao Tong University, Harbin Institute of Technology, Zhejiang University, Peking University, Nanjing Tech University, Nanjing University, Nanjing University of Posts and Telecommunications, Fuzhou University, and the Chinese Academy of Sciences. This list itself is a signal: the main battlefield of this instrument is universities and research institutes.
It is not for rapid testing on factory production lines (that is the job of the ATR6100/3100), nor for routine spot checks at quality inspection centers. It is for people doing basic research in laboratories—nanomaterial characterization, polymer blend films, forensic trace evidence, gemstone and mineral identification, biomedical coatings, and water pollution particulate analysis. These scenarios share common features: small sample amounts, micro-scale areas, the need for two spectroscopic methods to cross-validate each other, requirements for resolution and signal-to-noise ratio, and data that must be publishable in papers.
06 What It Is Not Suitable For
After discussing capabilities, the boundaries must be made clear.
First, it is not rapid testing equipment. A single mapping image may take tens of minutes to several hours. It answers “what is the composition of this micro-area and how is it distributed,” not “give a result in three seconds.”
Second, it requires professional operation. Optical path switching, wavelength selection, objective magnification, integration time, and fluorescence suppression all require trained personnel. It is not a device that can be placed in a laboratory and run automatically.
Third, it cannot replace other analytical methods in the laboratory. XRD for crystal structure, SEM for morphology, GC-MS for quantitative composition—it does none of these. It is a supplement for micro-area molecular vibrations, not an all-around performer.
Fourth, spectral interpretation of complex mixtures has a threshold. Raman and infrared spectra overlap, and peak assignment requires experience. The instrument gives data; conclusions rely on people.
Fifth, it is not inexpensive. As a research-grade integrated instrument, its procurement cost is far higher than portable devices. Whether it is worth buying depends on whether the research group’s direction truly requires combined micro-area Raman + infrared characterization.
In one sentence: the ATRP8300Pro solves not the question of “whether it can measure,” but the question of “measuring the same micro-area with two methods simultaneously, without positional misalignment, and with automatic imaging.” If your research often involves moving samples back and forth between the Raman room and the infrared room, this is the instrument you need.