Applications | ATL3100 2-Second Precious Metal Analysis
Identify Gold, Silver, Platinum, and Palladium Purity On Site in 2 Seconds
A tray of incoming material is placed in front of you: gold bars, silver ingots, K-gold jewelry, and platinum/palladium sheets mixed together. The first task is to sort them. A difference of one part per thousand in purity changes the settlement price and downstream process. Which piece can be priced directly, and which must be sent for testing first? The naked eye and touch cannot provide the answer. What is needed on site is very specific: hold the sample in hand for two seconds and first see the compositional profile of the main element and alloying/additive elements. The final report can be supplemented later.
Precious metal incoming materials: gold bars, silver ingots, and Pt/Pd sheets are first sorted by composition before determining sorting, pricing, and testing paths.
01 Why Can’t Precious Metal Purity Wait?
Purity is ultimately a question of ratio. Fine gold, 18K gold, 925 silver, Pt950, and Pd950—these designations specify how much of the main element and additive elements are present.
Reading it urgently on site is for the following tasks:
• Pricing and settlement by purity: recycled materials, old materials, and scrap all rely on this for sorting and pricing.
• Determining designation and process: K-gold additive ratios and the processing performance of platinum/palladium alloys depend on the elemental spectrum.
• Flagging suspicious items: plated, gold-filled, and core-doped items are marked first, then sent to the laboratory for valuation.
• Elements that must be seen in advance: Cd in silver alloys and Ni in K-gold.
• Batch consistency checks: before furnace batching and finished product release.
The bottleneck is speed. Sampling, dissolving, weighing, running the instrument, and issuing a report—a laboratory round takes hours or even days. Sending a whole tray of mixed incoming materials piece by piece is neither cost- nor time-effective. What is truly lacking on site is a judgment that can be made on the spot: should this piece be sent for testing?
02 From “Send to the Laboratory” to “Get Results on the Spot”: How LIBS Reads Composition
Cupellation (fire assay), ICP subtraction, and gravimetric methods are used for valuation. Their accuracy is not in question, but the cost is destructive sampling and complex pretreatment. Laser-induced breakdown spectroscopy (LIBS) takes another path: the laser directly hits the solid sample, multiple elements are analyzed simultaneously, and almost no pretreatment is required.
A high-energy pulsed laser is focused onto the sample surface. A micro-area of material is instantly ablated and vaporized, forming plasma. Excited atoms and ions emit their characteristic spectral lines when they relax: the wavelength tells which element it is; the intensity, after calibration, gives the content. A single excitation can simultaneously obtain information on Au, Ag, Pt, Pd, and associated elements—this is what enables second-level results.
XRF and LIBS are both surface micro-area analysis techniques, but they read different signals: XRF reads characteristic X-rays, while LIBS reads atomic emission lines from plasma. The excitation source of the latter is a laser, not an X-ray tube. A single excitation leaves only a micrometer-scale ablation spot on the surface, with minimal sample consumption; the same sample can be measured again at another point.
The boundary must also be made clear: LIBS measures a surface micro-area. Plating, gold-filled layers, oxide films, oil contamination, and solder joints can all cause a single reading to deviate from the bulk composition. Cleaning before measurement, avoiding weld seams and settings, and averaging multiple points are steps that cannot be skipped. If skipped, no matter how fast the 2-second result is, the conclusion will not hold.
03 ATL3100 Handheld Alloy Laser-Induced Breakdown Spectrometer
The ATL3100 is Optosky’s handheld laser-induced breakdown spectrometer for on-site alloy analysis. The whole unit weighs 1.75 kg (including battery). Solid samples are measured directly. After one-button triggering, it provides multi-element qualitative and quantitative results in 2 s and automatically compares them with the built-in alloy grade library. It runs on Android with a 5-inch capacitive touchscreen. A micro-area camera is used to aim at the measurement point, and a photo camera records evidence. Bluetooth / 4G / Wi-Fi / USB / GPS transmit data. With IP54 protection and 8-hour battery life, it can be carried to recycling sites, workshop furnaces, counters, and warehouses.
Beyond precious metals, it can also measure aluminum, copper, iron, nickel, titanium, and magnesium alloys. Positive material identification (PMI) uses the same instrument and the same grade library.
04 Gold, Silver, Platinum, Palladium: How to Use the Four Element Lists
A single main element cannot read out all the information. The ATL3100 alloy database is divided into element channels by matrix, and one measurement simultaneously provides the content of the main element and associated elements:
Gold alloys: Ag and Cu determine the color and hardness of K-gold; Zn, Ni, Pd, Co, and In are common in various additive formulations. Among them, Ni and Pd are typical additive elements in white gold alloys, and In is often used to improve casting and processing performance. Reading these elements together with the main Au helps distinguish fine gold, 18K white gold, and copper-zinc-based imitation items.
Silver alloys: Ag/Cu is the most common ratio framework; Zn is often used for deoxidation and improving fluidity; Cd appears in some silver brazing materials; Ni is mostly a trace element. Cd and Ni must be read on site first before deciding whether laboratory quantification is needed.
Platinum and palladium: Beyond the main Pt and Pd, Ru, Co, Cu, Ni, and Zn are often additive or associated elements in platinum-group alloys; Pd matrices also require attention to impurities such as Fe, As, Pb, and Cr. Sorting and valuation of spent catalysts, electronic pastes, and recycled materials are inherently based on this elemental spectrum.
With the four lists and automatic comparison against the grade library, the ATL3100 can provide qualitative and quantitative results for Au / Ag / Pt / Pd and alloying elements within 2 s. Items with purity clearly deviating from the target grade are picked out on the spot; those with matching composition proceed to the next process; suspicious items are sent to the laboratory for valuation.
05 How to Choose Standard Test Methods?
The standard system for precious metal testing has a clear division of labor: which methods are responsible for valuation and certification, and which are only responsible for screening—each has its place. Clarifying this layer first makes it easier to judge where the ATL3100 should be placed.
• GB 11887 Precious metal purity requirements and naming methods for jewelry: mandatory requirements for purity and naming; fine gold, platinum, palladium, and silver shall not be lower than 990‰.
• GB/T 9288-2019 Gold alloy jewelry—Determination of gold content—Cupellation method (fire assay): designated by GB 11887 as the arbitration method for gold content analysis, applicable to gold content of 333.0‰–999.5‰.
• GB/T 40114-2021 Jewelry—Determination of precious metal content—ICP subtraction method: determines impurity element content and subtracts to obtain the main element; applicable to gold 725‰–999‰, platinum and palladium 800‰–999‰ in jewelry.
• GB/T 18043-2013 Jewelry—Determination of precious metal content—X-ray fluorescence spectrometry: defines XRF determination of gold, silver, platinum, and palladium content as screening testing, i.e., preliminary quantification of the elements to be tested.
• GB/T 38257-2019 Laser-induced breakdown spectroscopy: general LIBS method, specifying terms and basic principles, test conditions, equipment and devices, samples, test procedures, data processing, and test reports; applicable to chemical element detection and analysis of solid, liquid, and gaseous substances.
Arbitration and valuation are left to laboratory methods; what is done on site is screening. The ATL3100’s 2-second result falls at the screening level: Au/Ag/Pt/Pd and other elements are measured as needed, and obviously non-conforming samples are first separated from the batch.
For settlement disputes, certificate issuance, or compliance determination, laboratory review according to the corresponding standard methods is still required.
To use these 2 seconds accurately, several actions are best written into the work instructions:
• Clean the measurement point before testing; if necessary, lightly polish a non-appearance surface to remove the oxide layer and plating (this will leave marks).
• Avoid solder joints, settings, and known plated areas; use the micro-area camera to aim at a flat surface.
• For samples with uneven composition, measure multiple points and average; mark abnormal readings separately.
• Regularly calibrate and verify with standard samples matching the matrix.
• For gold-plated, gold-filled, and internally doped suspicious items, always rely on laboratory methods.
06 One On-Site Inspection, Three Actions
In operation, there are just three steps:
Position: Clean the sample surface and aim the micro-area camera at the measurement point.
Trigger: Pull the trigger with one button; the 1535 nm laser completes micro-area excitation; after 2 s, read the multi-element content and matching grade on the screen.
Record: Store results as xlsx, take photos by point for archiving, export or upload via Bluetooth / 4G / Wi-Fi / USB, and use GPS to mark measurement point locations.
What Is Saved?
In the past, for a tray of material, one could mostly only rely on experience to pick a few pieces for the laboratory, and the rest were valued by batch. Now every piece can be checked with a point: those with obviously abnormal purity are picked out on the spot, matching ones flow normally, and laboratory testing is concentrated on a few suspicious items and batches requiring certification. The action is fixed into three steps: clean, aim, pull the trigger. Measurement point photos, xlsx results, and location information are kept together. If you want to check which piece or which point later, you can find it by reviewing the records.
Recycled material sorting, furnace batching verification, counter acceptance, and third-party testing preliminary screening all require the same thing: the compositional profile of Au/Ag/Pt/Pd, available on the spot. The ATL3100 does not replace laboratory arbitration methods. It moves two decisions forward to the two seconds when the sample is in hand: whether this piece should be sent for testing, and which category it should be sorted into first.
Suitable Customers
Precious metal recycling and refining enterprises · Jewelry processing and wholesale · Jewelry testing and quality inspection institutions · Pawnshops and counter acceptance · Platinum-group catalyst and electronic paste recycling · University and research metal materials laboratories..
For more information, please contact:
Email: [email protected]
Web: www.optosky.net
Precision fertilization by UAV for rice at tillering stage in cold region based on hyperspectral remote sensing prescription map