Spectrometer Comparison Guide
author: Susan
2021-09-23
Not sure where to start when choosing a modular spectrometer?
This chart compares our standard spectrometer models and their key features.
For further guidance, please contact us.
Explore Our Spectrometers

| ATP1010 | ATP2000 series | ATP3000 series | |
| Key Features: | Ultra-miniture UV-unhanced Attractive for integration and scalability |
Low unit-to-unit variation Super cost-effective Thermal stability |
High resolution Thermal stability Low stray light |
| Options Available within this Wavelength Range: | 180-1100nm(customizable) | 200-1100nm(customizable) | 200-1100nm(customizable) |
| Optical Resolution (FWHM): | 0.2-5 nm (Slit size & spectral range) | 0.1-3 nm(Slit size & spectral range) | 0.04-3 nm(Slit size & spectral range) |
| Preconfigured Models: | UV, Vis, NIR, Irradiance | UV-Vis, Vis-NIR, Extended Range | UV-Vis, Vis-NIR, Extended Range |
| Custom Configurations: | Yes | Yes | Yes |
| Applications: | Industrial and integration applications Laser characterization Plasma monitoring |
All-purpose lab use Irradiance measurements Life sciences measurements Water qulity |
Industrial and integration applications Laser characterization Plasma monitoring |
| Compatibility with Accessories: | Yes | Yes | Yes |
| Dimensions (mm): | 45×42×23 mm3(60g) | 102×72×36.3 mm^3(0.38kg) | 170×110×52 mm^3, equal to 6.7×4.3×2 inch(0.38kg) |
| ATP5020 series | ATP6500 | |
| Key Features: | High sensitivity Excellent UV response Miniatuer used in Raman |
High resolution Thermal stability Low stray light |
| Options Available within this Wavelength Range: | 180-1180nm(customizable) | 180-1100nm(customizable) |
| Optical Resolution (FWHM): | 0.06-2 nm (Slit size & spectral range) | 0.1-3 nm(Slit size & spectral range) |
| Preconfigured Models: | 532, 785, 633, 830 nm Raman series | UV-Vis, Vis-NIR, Extended Range, Absorbance, Fluorescence, Raman |
| Custom Configurations: | Yes | Yes |
| Applications: | Raman spectrometer Online Raman spectroscopy analysis Material identification Pharmaceuticals Analysis Medical & Life Science Energy, Oil & Gas Sorting fruits, plastics, polymers |
Fluorescence of biological samples DNA sequencing Raman analysis Microscale, fast spectrophotometer Transmittance measurement |
| Compatibility with Accessories: | Yes | Yes |
| Dimensions (mm): | 217×110×52 mm(1.6kg) | 217×110×52 mm^3(0.97kg) |
| ATP8600 | ATP8000 | |
| Key Features: | 256 pixels of InGaAs detector Custom configured Range: 900-1700nm Compact size fit to system integration Free NIR spectrometer software Lowest cost NIR spectrometer |
Enhanced optical bench and aperture design High SNR over a short integration period, ideal for samples moving quickly on a process line |
| Options Available within this Wavelength Range: | 900-1700nm(customizable) | 900-2500nm(customizable) |
| Optical Resolution (FWHM): | 4-20 nm (Slit size & spectral range) | 3-6nm (Custom configured grating grooves and slit size) |
| Preconfigured Models: | Standard version | 900-1700 nm 900-2100 nm 900-2500 nm |
| Custom Configurations: | Yes | Yes |
| Applications: | Food sorting Waste water detection Detection of moisture, protein, fat and fiber in crops Paper sorting Online monitoring of Chinese medicine production Solar panel inspection FBGA fiber modem Laser wavelength monitoring |
Moisture content for fruit sorting Plastics recycling Chemical concentration measurements |
| Compatibility with Accessories: | Yes | Yes |
| Dimensions (mm): | 102 x 57.5 x 29mm(280g) | 170×130×52.3 mm3(1.79kg) |
NIR Spectroscopy Identify the Plastics Recycling
How to Monitor Water Quality Once Japan's Nuclear Waste Water Enters the Sea
Related Article

The ATP7810 is a wide-band, high-resolution infrared grating spectrometer covering up to 0.9–5 μm. Featuring a motorized rotating grating, multiple detector options (InGaAs/MCT), and flexible interfaces (SMA905 or free space, USB/UART control), it delivers high SNR and stability for absorption/reflection/transmission spectroscopy, laser wavelength testing, and fiber optic sensing.
New Product Recommendation | ATP7810 Ultra-Wide Range Infrared Spectrometer Series
This study uses the ATP5200P UV-Vis spectrometer to investigate xanthate adsorption on chalcopyrite surfaces. By analyzing absorbance at 300 nm under controlled pH and temperature, the method optimizes flotation conditions for copper recovery, enabling real-time, sensitive detection of adsorption mechanisms in non-ferrous mineral processing.
Using the ATP5200P Spectrometer to Unravel Xanthate Adsorption and Separation Mechanisms
ATP1030 is an ultra‑compact, high‑resolution spectrometer covering 190–1100 nm. With a 1024‑pixel CMOS detector, adjustable integration time down to 1 ms, and USB‑powered design, it delivers reliable performance for applications like online water analysis, color measurement, handheld instruments, and Raman spectroscopy.
Product Recommendation | ATP1030 mini spectrometer Spectrometer
Vis-NIR transmission spectroscopy enables non-destructive identification of infertile duck eggs before incubation, achieving >95% accuracy. By detecting spectral fingerprints (e.g., 836 nm peak for fertile eggs), this method reduces energy waste and improves hatch rates, offering a low-cost, high-throughput solution for modern poultry farming.
Application case | How Spectral Technology is Transforming Duck Egg Farming